Semiautomatic Determination of Arterial Input Function in DCE-MRI of the Abdomen

Authors

  • Harrison Kim Department of Radiology, University of Alabama at Birmingham, 1670 University Blvd, Birmingham AL, USA, 35294-0019
  • Desiree E Morgan Department of Radiology, University of Alabama at Birmingham, 1670 University Blvd, Birmingham AL, USA, 35294-0019

DOI:

https://doi.org/10.14738/jbemi.42.3041

Keywords:

DCE-MRI, Arterial input function, Abdominal aorta, Automatic segmentation

Abstract

The goal of this study was to develop a semiautomatic segmentation technique of the abdominal aorta to determine the arterial input function (AIF).  A total of 24 patients having therapy naïve abdominal cancers were imaged using DCE-MRI on a 3T MR scanner.  DCE-MRI continued for 4.2 minutes with 2.1 seconds temporal resolution (120 acquisitions).  Gadoteridol (0.1 mmol/kg) was infused intravenously at 30 seconds after starting DCE-MRI, and flushed with 20-ml saline (2 ml/s).  Patients were instructed to hold breath after maximal inhalation, and repeat as needed to full inspiration.  The location of the abdominal aorta was manually identified, but its segmentation and motion tracking were automatically implemented.  AIFs determined in the aortic region with and without tracking motion were statistically compared.  The aortic region was further segmented into multiple smaller regions, and the AIF change according to the size of the region of interest (ROI) was examined.  The displacement of the abdominal aorta during DCE-MRI was 3.4±2.3 (mean±SD) mm.  The root mean square error (RMSE) of AIF from the best fitting curve was 0.110±0.010 mM after motion correction, which was significantly smaller than that before motion correction (0.134±0.016 mM; p<0.001).  The amplitude of AIF varied up to 15% according to the ROI size.  However, when the radius of ROI was reduced more than 3 mm, the variation in AIF amplitude was less than 5%.  Therefore the ROI having smaller radius than that of aorta will need to be used to determine a reliable AIF in abdominal DCE-MRI.

References

(1) Arevalo-Perez, J., et al., Dynamic contrast-enhanced MRI in low-grade versus anapestic oligodendrogliomas. Journal of neuroimaging, 2016. 26(3): p. 366-371.

(2) Wu, J., et al., Intratumor partitioning and texture analysis of dynamic contrast-enhanced (DCE)-MRI identifies relevant tumor subregions to predict pathological response of breast cancer to neoadjuvant chemotherapy. Journal of Magnetic Resonance Imaging, 2016. 44(5): p. 1107-1115.

(3) Berman, R.M., et al., DCE MRI of prostate cancer. Abdominal Radiology, 2016. 41(5): p. 844-853.

(4) Sun, B., et al., Lymphoma and inflammation in the orbit: Diagnostic performance with diffusion-weighted imaging and dynamic contrast-enhanced MRI. J Magn Reson Imaging, 2016.

(5) Zhu, J., et al., Can Dynamic Contrast-Enhanced MRI (DCE-MRI) and Diffusion-Weighted MRI (DW-MRI) Evaluate Inflammation Disease: A Preliminary Study of Crohn's Disease. Medicine (Baltimore), 2016. 95(14): p. e3239.

(6) Boesen, M., et al., Correlation between computer-aided dynamic gadolinium-enhanced MRI assessment of inflammation and semi-quantitative synovitis and bone marrow oedema scores of the wrist in patients with rheumatoid arthritis--a cohort study. Rheumatology (Oxford), 2012. 51(1): p. 134-43.

(7) Calamante, F., Arterial input function in perfusion MRI: a comprehensive review. Prog Nucl Magn Reson Spectrosc, 2013. 74: p. 1-32.

(8) Yankeelov, T.E., et al., Evidence for shutter-speed variation in CR bolus-tracking studies of human pathology. NMR in biomedicine, 2005. 18(3): p. 173-85.

(9) Yankeelov, T.E., et al., Variation of the relaxographic "shutter-speed" for transcytolemmal water exchange affects the CR bolus-tracking curve shape. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine, 2003. 50(6): p. 1151-69.

(10) Logan, J., et al., Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects. Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism, 1990. 10(5): p. 740-7.

(11) Yin, J., J. Yang, and Q. Guo, Automatic determination of the arterial input function in dynamic susceptibility contrast MRI: comparison of different reproducible clustering algorithms. Neuroradiology, 2015. 57(5): p. 535-43.

(12) Peruzzo, D., et al., Automatic selection of arterial input function on dynamic contrast-enhanced MR images. Comput Methods Programs Biomed, 2011. 104(3): p. e148-57.

(13) Singh, A., et al., Improved bolus arrival time and arterial input function estimation for tracer kinetic analysis in DCE-MRI. J Magn Reson Imaging, 2009. 29(1): p. 166-76.

(14) Li, X., et al., A novel AIF tracking method and comparison of DCE-MRI parameters using individual and population-based AIFs in human breast cancer. Phys Med Biol, 2011. 56(17): p. 5753-69.

(15) Chen, J., J. Yao, and D. Thomasson, Automatic determination of arterial input function for dynamic contrast enhanced MRI in tumor assessment. Med Image Comput Comput Assist Interv, 2008. 11(Pt 1): p. 594-601.

(16) Sanz-Requena, R., et al., Automatic individual arterial input functions calculated from PCA outperform manual and population-averaged approaches for the pharmacokinetic modeling of DCE-MR images. J Magn Reson Imaging, 2015. 42(2): p. 477-87.

(17) Weisskoff, R.M., et al., Pitfalls in MR measurement of tissue blood flow with intravascular tracers: which mean transit time? Magn Reson Med, 1993. 29(4): p. 553-8.

(18) Perthen, J.E., et al., Is quantification of bolus tracking MRI reliable without deconvolution? Magn Reson Med, 2002. 47(1): p. 61-7.

(19) Peeters, F., et al., Inflow correction of hepatic perfusion measurements using T1-weighted, fast gradient-echo, contrast-enhanced MRI. Magnetic resonance in medicine, 2004. 51(4): p.

-7.

(20) Ivancevic, M.K., et al., Inflow effect correction in fast gradient-echo perfusion imaging. Magnetic resonance in medicine, 2003. 50(5): p. 885-91.

(21) Kim, H., et al., Dynamic contrast enhanced magnetic resonance imaging of an orthotopic pancreatic cancer mouse model. Journal of visualized experiments : JoVE, 2015(98).

(22) Roberts, C., et al., The effect of blood inflow and B1-field inhomogeneity on Measurement of the arterial input function in axial 3D spoiled gradient echo dynamic contrast-enhanced MRI. Magnetic Resonance in Medicine, 2011. 65: p. 108-119.

(23) Otsu, N., A threshold selection method from gray-level histograms. IEEE Trans Sys Man Cyber, 1979. 9(1): p. 62-66.

(24) Parker, G.J., et al., Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine, 2006.

(5): p. 993-1000.

(25) Neter, J., et al., Applied linear statistical models. Fourth ed1996, Columbus: The McGraw-Hill Companies, Inc.

(26) Hoffman, E.J., S.C. Huang, and M.E. Phelps, Quantitation in positron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr, 1979. 3(3): p. 299-308.

(27) Yin, P., Maximum entropy-based optimal threshold selection using deterministic reinforcement learning with controlled randomization. Signal Processing, 2002. 82(7): p. 993-1006.

(28) El-Zaart, A., Images thresholding using ISODATA technique with gamma distribution. Pattern Recognition and Image Analysis, 2010. 20(1): p. 29-41.

(29) Huang, Z., Chau, K., A new image thresholding method based on Gaussian mixture model. Applied Mathematics and Computation, 2008. 205(2): p. 899-907.

(30) Canny, J., A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell, 1986. 8(6): p. 679-98.

(31) Gao, W., et al., An improved Sobel edge detection. Computer Science and Information Technology, 2010: p. 67-71.

Berzins, V., Accuracy of laplacian edge detectors. Computer Vision, Graphics, and Image Processing, 1984. 27(2): p. 195-210.

Downloads

Published

2017-05-04

How to Cite

Kim, H., & Morgan, D. E. (2017). Semiautomatic Determination of Arterial Input Function in DCE-MRI of the Abdomen. British Journal of Healthcare and Medical Research, 4(2), 96. https://doi.org/10.14738/jbemi.42.3041